I am planning to make A arms and the push-rods using carbon fibre tubes.
How should I chose the inner dia and outer dia of the tubes so as to avoid failure.
provided the forces are
1903.803297 front lower A
2166.240985 rear lower A
414.642784 front upper A
394.6610908 rear upper A
all forces in lbs

Edited 12 Years Ago by sahil.tfateh
Replies
Warren (Staff)
Warren (Staff)
Supreme Being (22K reputation)Supreme Being (22K reputation)Supreme Being (22K reputation)Supreme Being (22K reputation)Supreme Being (22K reputation)Supreme Being (22K reputation)Supreme Being (22K reputation)Supreme Being (22K reputation)Supreme Being (22K reputation)
Group: Administrators
Posts: 2.5K, Visits: 8.5K
You will need to calculate the right tube specification.

The basic data for our range of roll wrapped tubes is:

                                                                                                                                                                                                                                                                                                
PropertyThis Carbon Fibre TubeSteelAluminium
Density (g/cc)1.608.02.7
Youngs Modulus 0°(GPa)9020772
Youngs Modulus 90°(GPa)1920772
In-Plane Shear Modulus(GPa)4.6--
Major Poisson's Ratio(MPa)0.14--
Ult. tensile Strength 0°(MPa)750990460
Ult. comp. Strength 0°(MPa)600990460
Ult. tensile Strength 90°(MPa)400990460
Ult. comp. Strength 90°(MPa)350990460


You will then need to use those figures and compare the calculations with the tube sizes we offer to see if the sizes are suitable for your needs.

Warren Penalver
Easy Composites / Carbon Mods - Technical Support Assistant
sahil.tfateh
sahil.tfateh
Forum Member (38 reputation)Forum Member (38 reputation)Forum Member (38 reputation)Forum Member (38 reputation)Forum Member (38 reputation)Forum Member (38 reputation)Forum Member (38 reputation)Forum Member (38 reputation)Forum Member (38 reputation)
Group: Forum Members
Posts: 4, Visits: 24
how to calculate the tube specifications from the given load
i am unable to find an approach
could you please guide ??
ChrisR
ChrisR
Supreme Being (2.8K reputation)Supreme Being (2.8K reputation)Supreme Being (2.8K reputation)Supreme Being (2.8K reputation)Supreme Being (2.8K reputation)Supreme Being (2.8K reputation)Supreme Being (2.8K reputation)Supreme Being (2.8K reputation)Supreme Being (2.8K reputation)
Group: Forum Members
Posts: 363, Visits: 3K
You need to calculate look at the arrangement you are going to use, calculate the forces (which you have calculated axial by the looks of it) but is there any bending or shear induced due to the mounting type?

Then design separately for:
Pure Axial tension
Pure Axial compression
Axial tension / compression with nominal bending from the axial force and a nominal lever arm
Bending moment capacity
Buckling moment capacity
Combined buckling and axial forces (tension and compression)

Then:
Check deflection in all load cases for calculated stiffness of tube and arrangement.

The tube will most likely be a combination of UD at 0, +/-45 and 90deg to the C/L