Any Ideas/Help


Author
Message
easby
easby
Forum Guru (63 reputation)Forum Guru (63 reputation)Forum Guru (63 reputation)Forum Guru (63 reputation)Forum Guru (63 reputation)Forum Guru (63 reputation)Forum Guru (63 reputation)Forum Guru (63 reputation)Forum Guru (63 reputation)
Group: Forum Members
Posts: 6, Visits: 44
Any thoughts what is causing this? Part is wet lay then bagged.
Thanks
Attachments
Carbon Part.jpg (613 views, 3.00 MB)
Replies
Fasta
Fasta
Supreme Being (4K reputation)Supreme Being (4K reputation)Supreme Being (4K reputation)Supreme Being (4K reputation)Supreme Being (4K reputation)Supreme Being (4K reputation)Supreme Being (4K reputation)Supreme Being (4K reputation)Supreme Being (4K reputation)
Group: Forum Members
Posts: 468, Visits: 3.5K


I would say that this air is fairly normal for a wet laid part and vacuum bagging.

If you want good cosmetic parts for wet laid method then the part shape needs to be very simple so that you can remove the air either by rollers, squeegee or even hand massaging the carbon. Then no vacuum is needed.

Or change to vacuum infusion.




Zebra
Zebra
Supreme Being (104 reputation)Supreme Being (104 reputation)Supreme Being (104 reputation)Supreme Being (104 reputation)Supreme Being (104 reputation)Supreme Being (104 reputation)Supreme Being (104 reputation)Supreme Being (104 reputation)Supreme Being (104 reputation)
Group: Forum Members
Posts: 14, Visits: 32
Fasta (15/07/2016)


I would say that this air is fairly normal for a wet laid part and vacuum bagging.

If you want good cosmetic parts for wet laid method then the part shape needs to be very simple so that you can remove the air either by rollers, squeegee or even hand massaging the carbon. Then no vacuum is needed.

Or change to vacuum infusion.


Nonsense. It is totally possible to achieve a nice finish with parts far more complex than this with a wet lay up. I do it all the time. It's all about the process.



Wet the material on a flat smooth surface and squeegee all the air bubbles out before you lay the first layer. Squeegee the cf between 2 layers of smooth material like release liner so you can see that all the air bubbles are removed. Wait until the cf starts to gel and become tacky before removing the release liners and then lay it in the mold. Once the resin has started to gel, no more air bubbles will be able to get into the surface unless your mold surface is not smooth or has cavities. 

When tacky, the cf will still to the mold nicely which also prevents more air bubbles.

If the vacuum is not holding the material in place properly, use a rigid plug to hold the cf against the mold and, if needed, use C clamps to apply pressure.

Good luck
Rovinmosin
Rovinmosin
Junior Member (22 reputation)Junior Member (22 reputation)Junior Member (22 reputation)Junior Member (22 reputation)Junior Member (22 reputation)Junior Member (22 reputation)Junior Member (22 reputation)Junior Member (22 reputation)Junior Member (22 reputation)
Group: Forum Members
Posts: 4, Visits: 97
Can you use a rigid a plug with the infusion process as well or would it affect the resin flow?