Dear all. I got a problem with a new bio-resin. During the degassing, if I fill the the calibrated mixing cup (2440ml) up to 700ml, bubbling is quite large and I got a huge loss of resing, I am attaching a picture to show what is happening. Do you have any advice to avoid the loss of resin?
How this operation is usually done industrially? Do they use vacuum mixing or something like this?
Thank you in advance for your help.
Reply
Like
4
GO
Merge Selected
Merge into selected topic...
Merge into merge target...
Merge into a specific topic ID...
Open Merge
Threaded View
Threaded View
Degassing
Raf4C
-
3 Years Ago
You need a bigger cup. Some resins and especially silicones can froth up to several times their original volume, so you need a bigger cup to ensure it does not overflow. In some resin casting...
Warren (Staff)
-
3 Years Ago
Thank you Warren for your help.