Talk Composites - The Forum for Advanced Composites

Post Curing Uni-Mould System

http://www.talkcomposites.com/Topic15556.aspx

By ECV3 - 3/12/2015 11:54:28 AM

Can anyone give me advice on post curing uni-mould system moulds for use with low to mid temp pre preg. On EC's pdf it says-

10hrs at 60c >  2hrs at 70c >  2hrs at 80c >  2hrs at 90c

My question is are times and temps correct and do i need to use specific Ramp Rates?

Cheers!
By Warren (Staff) - 3/12/2015 12:41:54 PM

The temperatures and times are correct.